bradley m.

Complete: 1System Amana Split HP: HO said unit just didn’t seem to be keeping up. 1. He had the Nest learning features on the Tstat. So I removed all that. 2. His SH and SC was 14 and 7 but only a 14° drop. Adjusted txv and added 8oz of 410 and gained a 8° SH and 8° SC with a 19° drop. Tstat satisfied at 67°. Explained all my findings to mr Godwin and system is working great at this time.

Near Meadowbrook Rd, Benson, NC 27504
Logan S.

Logan S.

American standard heatpump inspection

Near Hunterwood Pl, Benson, NC 27504
Juan S.

Juan S.

2.5 tons heat pump Goodman

Near Josie Dr, Benson, NC 27504
David  M.

David M.

Rheem gaspack no heat

Near NC-242, Benson, NC 27504
Logan S.

Logan S.

Trane Split heat pump. Found bad condenser fan motor.

Near S Lincoln St, Benson, NC 27504
Manuel M.

Manuel M.

Complete 2 System 1 Amana and 1 Carrier HP Split Systems. Came to perform Heating Maintenance Right Carrier HP Split System: Checked Air Filters and thermostat. Checked blower motor and heat strips amp draws. Checked run cap. Inspected evap coil. Made sure drain line was clear. Checked all wiring at AH. Checked compressor and CFM amp draws. checked dual cap. Checked pressures. Tested defrost board. Cleaned condenser. Checked all wiring at condenser. System is running great at this time. Left Amana HP Split System: Checked Air Filters and thermostat. Checked blower motor and heat strips amp draws. Inspected evap coil. Made sure drain line was clear. Checked all wiring at AH. Called BJ to get settings right for best thermostat. Checked compressor and CFM amp draws. checked dual cap. Checked pressures. Tested defrost board. Cleaned condenser. Checked all wiring at condenser. System is running great at this time.

Near Tarheel Rd, Benson, NC 27504
Logan S.

Logan S.

Replaced outdoor ambient sensor on Ruud split heat pump

Near Miller Rd, Benson, NC 27504
bradley m.

bradley m.

Complete: 2 systems worked on DS Goodman Gas Pack: HO said system wouldn’t come on although the Tstat was saying it was on. She would literally push the reset button on her Tstat and it would come on. It wwould satisfy and she later would come back and turn it on and system wouldn’t come on and she would then reset it again. Everything system wise was working how it was supposed to. After cycling several times. Replaced Tstat with pro select tstat. Cycled system and is working great at this time.

Near NC-27, Benson, NC 27504
Ian G.

Ian G.

Servicing air conditioning system heat pump

Near NC-50, Benson, NC 27504
Thomas H.

Thomas H.

Trane split heat pump. Replaced bad compressor and recharged system

Near Lansing Dr, Benson, NC 27504
Dror S.

Dror S.

Goodman gas furnace replaced blower motor and capacitor found bad blower wheel part ordered

Near Dragstrip Rd, Benson, NC 27504
Dennis T.

Dennis T.

Found motor brok motor bracket on Goodman gas furnace

Near Dragstrip Rd, Benson, NC 27504
Shawn M.

Shawn M.

Bad blower motor on goodman split system straight ac

Near NC-27, Benson, NC 27504
Thomas H.

Thomas H.

York sp.it heat pump. Rep?ACED BAD DRAIN LINE float switch and replaced bad air handler breaker. Cheched for proper operAtion.

Near Rockvale Ct, Benson, NC 27504
Thomas H.

Thomas H.

Goodman split heat pump. Replaced bad contactor and duel capacitor. Diagnosed compressor over amping on start up

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Goodman split heat pump. Replaced leaking evap coil and recharged system

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Comfort maker straight a.c.. Added hard start to help compressor

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Goodman split heat pump. Replaced bad blower relay board

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Trane split heat pump. Replaced faulty defrost board and condenser fan motor

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Bryant split heat pump. Replaced bad contactor

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Amana gas package unit Adjusted burners

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Rheem gas package unit cooling maintenance

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Carrier straight a.c. cooling maintenance

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Carrier gas package unit cooling maintenance

Near William Dr, Benson, NC 27504
Thomas H.

Thomas H.

Trane split heat pump. Replaced bad breaker

Near William Dr, Benson, NC 27504